Measuring range (FS) | 0~0.5m…200mH2O or 0~5KPa…2MPa |
Permissible overpressure | Two times of full–scale pressure |
Measuring media | The liquid compatible with 316 stainless steel ( Corrosion-proof type can be selected under special conditions) |
Overall accuracy | ±0.25%FS | ±0.4%FS | ±1%FS |
Long-term stability | Typical:±0.1%FS/year | Maximum:±0.2%FS/year |
Operating temperature range | Integrated: -20℃~70℃ | Split (plug-in):-20℃~80℃ |
Compensation temperature range | Integrated: -10℃~55℃ | Split (plug-in):-10℃~70℃ |
Zero-point temperature drift | Typical:±0.02%FS/℃ | Maximum:±0.05%FS/℃ |
Sensitivity temperature drift | Typical:±0.02%FS/℃ | Maximum:±0.05%FS/℃ |
Range of power supply | 12~36VDC(generally 24VDC) |
Signal output | 4~20mA/1~5VDC/ 0~5VDC |
Load resistance | ≤(U-12)/0.02 Ω |
Structural material | Enclosure: stainless stee1 1Cr18Ni9Ni | Diaphragm: stainless steel 316L |
Sealing: fluororubber | Cable:Φ7.2mm special PVC cable |
Insulation resistance | 100MΩ,500VDC |
Lightning protection class | Class III lightning design(10000V/5kA);optional(20000V / 10000A)under special conditions |
Protection class | Enclosure protection class IP68 |
Safety and explosion protection | Ex iaⅡ CT5 |
Response time | ≤2 ms |
Resolution | Infinitely small(theoretic),1/100000(normal) |
Thermal hysteresis | ±0.1%FS(typical value)) |
Weight | Approx.500g |